{"id":2586683,"date":"2023-11-16T07:15:18","date_gmt":"2023-11-16T12:15:18","guid":{"rendered":"https:\/\/platoai.gbaglobal.org\/platowire\/fda-provides-guidance-on-selecting-predicates-for-510k-submissions-devices-cleared-using-established-methods-or-devices-that-meet-expectations\/"},"modified":"2023-11-16T07:15:18","modified_gmt":"2023-11-16T12:15:18","slug":"fda-provides-guidance-on-selecting-predicates-for-510k-submissions-devices-cleared-using-established-methods-or-devices-that-meet-expectations","status":"publish","type":"platowire","link":"https:\/\/platoai.gbaglobal.org\/platowire\/fda-provides-guidance-on-selecting-predicates-for-510k-submissions-devices-cleared-using-established-methods-or-devices-that-meet-expectations\/","title":{"rendered":"FDA Provides Guidance on Selecting Predicates for 510(k) Submissions: Devices Cleared Using Established Methods or Devices That Meet Expectations"},"content":{"rendered":"

\"\"<\/p>\n

The Food and Drug Administration (FDA) plays a crucial role in ensuring the safety and effectiveness of medical devices before they reach the market. One of the pathways through which medical devices can gain FDA clearance is the 510(k) submission process. In a recent move to provide clarity and guidance to manufacturers, the FDA has issued new recommendations on selecting predicates for 510(k) submissions. The guidance emphasizes the importance of using devices cleared using established methods or devices that meet expectations as predicates.<\/p>\n

A predicate device is an existing device that is used as a reference point for comparison when seeking FDA clearance for a new medical device. The selection of an appropriate predicate is a critical step in the 510(k) submission process as it helps demonstrate substantial equivalence to the FDA. Substantial equivalence means that the new device is as safe and effective as the predicate device and does not raise any new questions of safety or effectiveness.<\/p>\n

The FDA’s new guidance aims to address concerns regarding the use of older predicates that may not reflect current technological advancements or safety standards. In recent years, there have been instances where devices with outdated predicates have been linked to safety issues or failures. This has raised questions about the adequacy of the 510(k) process in ensuring patient safety.<\/p>\n

Under the new guidance, the FDA encourages manufacturers to use predicates that are no more than 10 years old. This ensures that the comparison device is more likely to reflect current technological advancements and safety standards. However, the FDA acknowledges that there may be instances where older predicates are appropriate, such as when there are no newer devices available or when the new device incorporates only minor modifications.<\/p>\n

In addition to age, the FDA also emphasizes the importance of selecting predicates that have been cleared using established methods or devices that meet expectations. Established methods refer to devices that have been cleared through a well-established regulatory pathway, such as a premarket approval (PMA) application. These devices have undergone a rigorous review process and have demonstrated their safety and effectiveness.<\/p>\n

Devices that meet expectations are those that have been cleared through the 510(k) process and have performed well in the market. The FDA encourages manufacturers to consider devices that have a good performance record, low complaint rates, and no safety concerns. This ensures that the new device is built upon a solid foundation of safety and effectiveness.<\/p>\n

The FDA’s guidance also highlights the importance of transparency in the selection of predicates. Manufacturers are encouraged to provide a clear rationale for their choice of predicate, including a detailed explanation of why the selected device is appropriate and how it is similar to the new device. This helps the FDA in evaluating the substantial equivalence of the new device and ensures that the selection process is based on sound scientific principles.<\/p>\n

By providing clear guidance on selecting predicates for 510(k) submissions, the FDA aims to improve the overall quality and safety of medical devices. The use of newer predicates that reflect current technological advancements and safety standards will help ensure that patients have access to the most advanced and safe medical devices. Additionally, the emphasis on established methods and devices that meet expectations will further enhance patient safety by building upon devices with a proven track record.<\/p>\n

Manufacturers should carefully consider the FDA’s guidance when selecting predicates for their 510(k) submissions. By doing so, they can streamline the review process, increase the chances of FDA clearance, and ultimately contribute to the development of safer and more effective medical devices.<\/p>\n